I am in the process of buttoning up a Nitehawk conversion on my Voron. I also replaced my extruder thermistor with an OE replacement purchased from a reputable vendor.

Post setup, my heated bed is reading spot on (it’s 18.3 C in my basement aka 65 F). I verified that my extruder is also at ambient temperature by wedging a Thermapen under its silicone sock and letting it acclimate for 10 minutes. The I’m not sure why the extruder would be reading high.

I bought a spare thermistor and wired it in. The result was identical.

Thoughts? Ideas? I’m pretty sure I have the Nitehawk and thermistor set up correctly.

[extruder] step_pin: nhk:gpio23 dir_pin: nhk:gpio24
enable_pin: !nhk:gpio25
heater_pin: nhk:gpio9
sensor_pin: nhk:gpio29
pullup_resistor: 2200
sensor_type: ATC Semitec 104NT-4-R025H42G`

  • @[email protected]
    link
    fedilink
    English
    1
    edit-2
    19 hours ago

    If they’re on board that could be their idle ambient temps.

    The currents running through them, resistors, etc all generate some heat.

    I tend to look at board temps less about the environment and more about how the board is doing.

    Is it suddenly running very hot, etc.

    As for the extruder it is attached to a thermal mass. So it may take longer to adjust but you did say it’s been sitting there for a bit.

    • @[email protected]OP
      link
      fedilink
      English
      29 hours ago

      I am less concerned about the board temp and much more curiosity about the reported temporary difference between the extruder and bed.

      I totally agree that the nitehawk PCB temp is quite possibly normal.