• @[email protected]
            link
            fedilink
            English
            135 months ago

            No fuse, no way

            Why would I want a whole circuit to be cut because of a single device fault, and then have to spend time figuring out which device on that circuit actually has the fault.

            Plus if a device only needs 3A it shouldn’t be able to draw more

            • @[email protected]
              link
              fedilink
              English
              45 months ago

              and then have to spend time figuring out which device on that circuit actually has the fault.

              Usually that happens just when you plug it in so…

            • @[email protected]
              link
              fedilink
              English
              45 months ago

              Why would I want a whole circuit to be cut because of a single device fault

              Dunno, if I have a fault in my home, I want it to be spectacular.

              A couple of years ago I literally had massive blood pressure and walked like 2 km to go buy a box of fuses.

              Burning two fuses, I figured out one of the extension strips was bad.

              If I plug something in and half of my apartment goes black, TWICE, and needs a fuse replacement each time, maybe that thing needs to be tossed anuway. I’m no electrician, I can’t troubleshoot a power strip. It has served its years. Bye.

        • @[email protected]
          link
          fedilink
          English
          175 months ago

          Type G only exists because the British skimped on wiring after WW2 and needed to put a fuse in each plug for safety, hence the chonkiness.

        • @[email protected]
          link
          fedilink
          English
          135 months ago

          Can’t rotate type G 180°. And since type F sockets are recessed, it’s just as unlikely to get shocked as with type G. Ground even connects first. And it’s directly compatible with type C and most type E plugs (since E&F usually share the same plug design, just the socket is a little different). What advantage would type G have to F?

        • @[email protected]
          link
          fedilink
          English
          85 months ago

          Go watch any video comparing plugs and I bet the majority say Type G. It has so many safety features it’s unreal.

          • @[email protected]
            link
            fedilink
            English
            155 months ago

            Which are only necessary because British houses are wired with a ring main. It’s a false economy.

            Also, when it was created, most appliances were earthed. Nowadays, most things one plugs in are small electronic devices which don’t need an earth. Type G/BS1363 has no 2-pin variant, and even mandates a mechanical shutter to prevent a plug without an earth pin from being used. Which was great in 1947, but not so much now, when Europeans, Americans, Japanese, Australians and such have slender 2-pin plugs and economical sockets to put them in, while the Brits/Irish/HK/UAE are stuck with their enormous clownshoe of a plug.

            • @[email protected]
              link
              fedilink
              English
              55 months ago

              I would have thought two pin plugs are easily to break. I’ve not broken a British plug in 40 years of life.

              Anyway I’m not trying to debate this. There are plenty of resources online where electricians discuss the different plug types and the order is typically UK, Germany, and Australia.

              • @[email protected]
                link
                fedilink
                English
                25 months ago

                What I’d like to see is apples-to-apples comparison of home and office safety between the different plug types. The data is sorta out there, but it’s not normalized in a way that’s convenient for comparison between countries.

                On paper, yes, the North American plug is pretty bad, but will that show up in actual practice? There may be a case for changing it, but that needs a comprehensive study before going to all the effort to transition to a better design. Even if we had that study right in front of us, I can already hear conservatives complaining about Marxists electrical plugs.

      • DacoTaco
        link
        fedilink
        English
        95 months ago

        What makes it better over a type e? Personally i prefer type e, i dont trust the springs of type f :')

            • JustEnoughDucks
              link
              fedilink
              English
              25 months ago

              It’s AC. Polarity doesn’t generally matter.

              Bridge rectifiers are also not polarized to convert AC to DC.

            • @[email protected]
              link
              fedilink
              English
              15 months ago

              In terms of physics, AC doesn’t have polarities. Treat both the live and the neutral wire as if it were live. You don’t know what kind of psychopath wired the building.

          • DacoTaco
            link
            fedilink
            English
            35 months ago

            Thats a fair argument that people have had issues with actually! Sometimes that is annoying but ive never had to much issues with it tbh

            • @[email protected]
              link
              fedilink
              English
              6
              edit-2
              5 months ago

              What’s great is that it’s also “backwards-compatible” with type E. Male type E plugs will usually also have ground connections for a type F, so you can plug it into female E and F sockets.

              Edit: In fact, looking back at the picture, that’s exactly the kind of male plug shown for both type E and F. It works with both types. It has the hole for an earth prong, but it also has a contact on the bottom side if you look closely.

              • DacoTaco
                link
                fedilink
                English
                3
                edit-2
                5 months ago

                I will say the comparability is amazing and a really good thing! The type f plugs are amazing. Nothing bad about more ground connections!
                Just wished the type f sockets had a solid piece of metal, instead of the springs. Then they’d be perfect! :D

    • Resol van Lemmy
      link
      fedilink
      English
      65 months ago

      That plug is only useful for a device that pays respects and nothing else.

  • @[email protected]
    link
    fedilink
    English
    365 months ago

    The plug design from my country looks elegant and rational, all the rest are koo-koo-krazy-town.

    – everyone

  • @[email protected]
    link
    fedilink
    English
    275 months ago

    Why would they invented a plugs that’s not grounded? (Type A and C)

    I fucking hate it because my country’s default plugs is type C. Caused me so much trouble in damaged electronics, shocked, and the effort to make a grounded line for each individual electronics myself.

    • @[email protected]
      link
      fedilink
      English
      255 months ago

      the non grounded plugs are usually only used on double isolated devices, like your phone charger.

      double isolated basically means all the outputs are only referenced to each other and not to ground, so you won’t get a shock by touching a usb plug, where you absolutely would if you touched live wire, where the reference is earth

      • @[email protected]
        link
        fedilink
        English
        65 months ago

        my pc case shocked me when I touched it, not a huge shock like live wires but enough for you to feel a little pain (like static shock on winter day). My phone charger also shocked me the same way when i touched the metal part of the USB head.

        • @[email protected]
          link
          fedilink
          English
          85 months ago

          yea PC power supplies do need the earth pin, but i’m surprised the usb also shocked you, maybe a faulty adapter?

          • @[email protected]
            link
            fedilink
            English
            45 months ago

            It’s a $80 GAN charger from Ugreen and the C-to-C cable that came with my iPhone.

            I would be a big sad chump if it’s a faulty brick. But thanks, I’ll find a way to troubleshoot that.

    • @[email protected]
      link
      fedilink
      English
      95 months ago

      Type c is commonly used in my country for small appliances as it can be used with type E and F plugs which are used everywhere

    • @[email protected]
      link
      fedilink
      English
      95 months ago

      Remember, all this stuff started over a century ago. The main application was electric incandescent lights, which are fine to run with only two wires.

    • @[email protected]
      link
      fedilink
      English
      45 months ago

      Your neutral should be bonded to ground anyway. If you have current on the neutral that needs the ground path, something is wrong.

    • @[email protected]
      link
      fedilink
      English
      35 months ago

      Does Finland use C outlets, though?

      At least in the US, just about every outlet has a ground port (Type B), even if the device you’re plugging in has only a 2-prong plug. I’ve only seen the Type A outlet in one really old building.

      • @[email protected]
        link
        fedilink
        English
        65 months ago

        Lots of old houses in the US still have a bunch of the Type A outlet. My first apartment did for most outlets.

        Now, what’s really fun is Knob and Tube wiring, where the hot and neutral lines are separate wires. Which means they tended to be run in separate directions if it was convenient for the asshole from a century ago to run it that way.

    • @[email protected]
      link
      fedilink
      English
      25 months ago

      A is much less of a pain than C. At least in most cases the plug pinches into the outlet and stays in place.

      I’ve used C while traveling for my charger and The weight of a few cords wants to drag that fucker out every time.

      Also worth noting that A can come in the polarized (one plug slightly larger, fits one way) or non-polarised (doesn’t matter) variety.

    • @[email protected]
      link
      fedilink
      English
      15 months ago

      Why would they invented a plugs that’s not grounded?

      Because the importance of grounding was something we figured out after those plugs were invented?

  • @[email protected]
    link
    fedilink
    English
    26
    edit-2
    5 months ago

    I wish the entire world would use type G. It’s the objectively superior socket for so many reasons. I hate type B so much

    • @[email protected]
      link
      fedilink
      English
      485 months ago

      Schuko (type F) is better than the UK plug. UK plug is huge, and schuko has same safety features, except the fuse, which is not needed if your houses would be build better.

      • @[email protected]
        link
        fedilink
        English
        285 months ago

        Local fusing provides notable advantages, even without ring finals. In particular, one failed appliance doesn’t necessarily take out the whole circuit, and lower draw appliances can be more closely fused (e.g. 3A) reducing available fault energy.

        • @[email protected]
          link
          fedilink
          English
          245 months ago

          It’s not worth the trade off of the giant plug in my opinion. And local fusing doesn’t really protect the user directly, it protects the wires. Modern codes in Europe put the equivalent of GFCIs on all circuits which can actually save lives.

          • @[email protected]
            link
            fedilink
            English
            6
            edit-2
            5 months ago

            GFCI will save people from direct shock , but won’t always stop a fault from say starting a fire. Example a damaged wire arcing the live and neutral (not a dead short) won’t trip gfci, there is no ground fault because the power is returning over the neutral as it should. And since it’s just a partial arc short it’s not going to draw enough to trip the main breaker so it can just sit there and get hot and catch fire.

            Technically we now have AFCI to try and detect exactly that, but it’s still relatively recent and generally very expensive to implement.

            All that said, I prefer the g-type outlet simply because of the giant plug ensures a nice, proper, secure connection, and isn’t shaped in a way that lends itself to being particularly damaged. Even if something lands on it, it’s profile prevents it from being ripped out of the socket. Whereas the other socket types tend to stick out quite far from their socket and have a tendency towards being yanked out of it. Obviously I’m partially overreacting because I’m dealing with the absolutely fucking garbage type B Outlet I just want an outlet that will finally stay secure

            • @[email protected]
              link
              fedilink
              English
              15 months ago

              To add, we upgraded our house from 100A to 200A service a little while ago, and one of the companies quoted an AFCI box. Was something like $15k, compared to like $3k for a much simpler setup (which left our existing 100A box as a subpanel instead of moving everything).

              Also, I run 3D printers, and apparently those tend to trip AFCI.

            • @[email protected]
              link
              fedilink
              English
              1
              edit-2
              5 months ago

              This is why both (fuse+GFCI) are put to the line and located in the electrical cabinet.

              • lazynooblet
                link
                fedilink
                English
                15 months ago

                Still not nearly as safe. Leaving it up to the home owner to replace the fuse/breaker for each circuit each time a device of a different amp requirement is used is very… naive? The manufacturer of the device shipping the item with the fuse that matches requirement is easier and safer. It may have been born from the ring mains requirement but it’s much safer because of it.

                • @[email protected]
                  link
                  fedilink
                  English
                  3
                  edit-2
                  5 months ago

                  Those fuses that can be changed by home owner themself have not existed in 20 years, all are automatic that you just flip from the panel. Fuse size is calculated based on the width of the cable, so if current gets too high the fuse just flips, so the cable doesn’t melt.

                  Edit: as a counter part, if you plug multiple high usage components on same cable, the individual device/plug fuse does not blow, but the cable can melt inside the wall.

                • @[email protected]
                  link
                  fedilink
                  English
                  15 months ago

                  IIRC, the UK actually teaches kids how to wire plugs properly in school for that very reason. Or at least they used to.

          • @[email protected]
            link
            fedilink
            English
            35 months ago

            What’s wrong with a large plug? Surely it’s better for people with mobility difficulties in their hands, like arthritis.

            • @[email protected]
              link
              fedilink
              English
              15 months ago

              I’d argue the recessed nature of a type F socket and the guides on the sides are much better suited for aiding those people.

          • @[email protected]
            link
            fedilink
            English
            15 months ago

            Built in fuses protect only downstream of where the fuse is. The supply flex is therefore not protected, despite often being the most damaged part.

    • @[email protected]
      link
      fedilink
      English
      105 months ago

      It’s absolutely overkill for many applications, with its integrated fuse, and that’s why I love it. It is indeed objectively best.

      • @[email protected]
        link
        fedilink
        English
        215 months ago

        Rest of Europe doesn’t like or use type G. It is bulky, can be used as a weapon, can only be plugged one way and compensates for shitty wiring that no one else needs or wants.

  • @[email protected]
    link
    fedilink
    English
    195 months ago

    Can I point out the UK BS1363 (type G) plug is the only one you can use to open a bottle of beer.

    I’m not sure what that says about the UK.

    • @[email protected]
      link
      fedilink
      English
      185 months ago

      German here. I’m absolutely positive I could open a beer with any of those plugs. And half of the sockets.

      • @[email protected]
        link
        fedilink
        English
        11
        edit-2
        5 months ago

        A fair point, but ours is practically a bottle opener. A lot easier after a few previous bottles.

  • @[email protected]
    link
    fedilink
    English
    14
    edit-2
    5 months ago

    What we really need is a USB-C-style reversible plug with data and variable voltage where neutral and phase never reverse and earth is always there.

    Lacking that, I vote for Type N because it’s small, polarised, and the pins are halfway-insulated. I don’t like that the frame is symmetrical, so in the dark, the only way to tell which way to plug in is to feel the pins and the holes, same as USB-A. I reject all that hurt to step on.

  • @[email protected]
    link
    fedilink
    English
    135 months ago

    Type B seen some shit, and it is probably Type-I’s fault. Regardless, I want whatever life strategy Type-K’s figured out.