I know that the answer is yes, I should, but outlets near the setup are not grounded (even though they look like they are) and I don’t want to have wires running though my living room.

The real question is what are potential problems ? Occasional system reboots? Permanent damage to PSU? Permanent damage to other components?

  • @[email protected]
    link
    fedilink
    English
    54
    edit-2
    5 months ago

    It will not affect system stability, but… Surge protectors do not work at all without a ground wire to drop excess voltage to. Any kind of line voltage disturbance could kill every device.

    Additionally, without any ground wire to pull the housings of devices to ground, the potential for a short to energize the case and then electrocute you is also high.

    additionally additionally, if you have grounded outlets that don’t actually have a ground connection running to them, that means either the wiring system is broken or it was “updated” by an unlicensed hack job who has undoubtedly made numerous more dangerous decisions elsewhere in the circuit.

    If your house is entirely ungrounded you really should have an electrician come update it ASAP. Outlet grounds have been mandatory since 1971. The chances are high that wiring predating that code is still using old cloth-wrapped wire insulation or even knob&tube, both of which are huge fire risks as the insulation is decayed badly by now. It’s expensive to have all new wire pulled but it is necessary.

    • Ebby
      link
      fedilink
      English
      195 months ago

      Can confirm. Neighbors house had an attic fire with knob & tube wiring.

      … Just like the stuff still in my place today. Eek! Landlord won’t upgrade unless there is a problem. In my house, the breakers are all 20amp and that’s a lot to run on, best guess, 70 year old wires.

      Oh, and do not assume anything is wired as expected. Test after. I’ve found a couple plugs “upgraded” to 3-prong by jumping the load and ground together. That made for a fun firework show when my metal fan touched something metal. Even the landlord was impressed by that stupidity.

      A cheaper solution is to take a copper wire and connect the ground screw of the socket to a water pipe. It does the job and is better than nothing.

        • @[email protected]
          link
          fedilink
          English
          115 months ago

          Second note, the metal pipe has to be continuously metal from at minimum where it enters the house, don’t trust that if you see a metal water pipe (or drain pipe) that it’s grounded.

      • @[email protected]
        link
        fedilink
        English
        85 months ago

        Looks like your landlord and the people who flipped my house hired the same electrician. They did the same stupid thing jumping the load and ground so that it’d pass inspection (the little tester will show everything properly grounded).

        Unnnnfortunately, that’s also a good way to cause serious damage to things and in my case it managed to short in such a way that it melted one of the phases coming into the house and damn near burned my house down.

        Don’t do stupid shit with your outlets, kids, because uh, yeah, fire.

      • @[email protected]
        link
        fedilink
        English
        2
        edit-2
        5 months ago

        I’ve found a couple plugs “upgraded” to 3-prong by jumping the load and ground together. That made for a fun firework show when my metal fan touched something metal. Even the landlord was impressed by that stupidity.

        Ah, the good old reverse polarity bootleg ground.

        Fun fact: RPBG is the one fault that those plug-in outlet testers can’t recognize

        Edit: Wait, no, that would be hot bootleg ground, they should catch that. RPBG has the hot and neutral switched, and also a bootleg ground to the neutral that’s actually hot

      • @[email protected]
        link
        fedilink
        English
        65 months ago

        Heh. House I rented was built before ubiquitous electricity. At some point, someone slapped a fuse box on the outside of the back wall and drilled a bunch of 1" holes in said wall to pass wiring. House was built on piers, so they just dragged wires around to places where they wanted outlets, which were mostly planted in the floor. Not a ground wire on site. I have no idea how they got away with renting that out, but it’s not like I called code enforcement, either.

        • @[email protected]
          link
          fedilink
          English
          25 months ago

          Generally speaking most buildings can be “grandfathered in” under code such that it’s perfectly legal to rent as long as the electrical system functions and meets code for the year on which it was built or installed… shitty, but legal.

        • @[email protected]OP
          link
          fedilink
          English
          25 months ago

          My house was built in 1939. Initial installation of ecectric cables consisted of a wire in a sleeve filled over with concrete. That was all replaced with proper tubing and isolation, but these few outlets do not have ground.

    • @aubeynarf
      link
      English
      45 months ago

      Surge suppressors do not drop extra voltage to ground. They selectively short out surges between whatever two conductors have a high potential between them.

      No ground conductor means there cannot be a high potential between it and anything else!

    • @[email protected]
      link
      fedilink
      English
      45 months ago

      Additionally, without any ground wire to pull the housings of devices to ground, the potential for a short to energize the case and then electrocute you is also high.

      this will also cause resets and instability. have seen it first hand.

  • @[email protected]
    link
    fedilink
    English
    235 months ago

    Permanent damage to PSU? Permanent damage to other components?

    Or worst: permanent damage to yourself.

  • @[email protected]
    link
    fedilink
    English
    125 months ago

    Without a ground there is nowhere for a surge to go, permanent damage is much more likely. Surge protectors or a UPS will not protect against surges at all without a ground.

    There’s also no ground so the chassis may have enough voltage on it to cause a shock if you touch it. This could also damage components as they are not grounded and touching things can introduce high voltage from static electricity which will have nowhere to go.

    Additionally if you have ethernet connected to it the system may end up grounding itself through the ethernet cable, if the device at the other side does have a ground, which could cause issues.

    So it basically just means you have a much higher chance of damaging the parts, or injuring someone touching things.

    • @[email protected]
      link
      fedilink
      English
      35 months ago

      You are correct that this is technically in code and would protect against shock hazards in a neutral error situation but you also get the opportunity for the outlet to pop during the day when nobody is home and the battery to die.

      We had a situation in our old house where someone who was technically correct but didn’t think it through had a gfci outlet upstream of the refrigerator outlet. Thankfully it popped while someone was home and we got everything corrected before we lost everything in the fridge.

      • Possibly linux
        link
        fedilink
        English
        3
        edit-2
        5 months ago

        You food should expire that quickly. It would take at least a day or two.

        Unless your gone for a while you would notice that the lights no longer on and it doesn’t feel as cold.

  • Krafting
    link
    fedilink
    English
    25 months ago

    Other question for anyone listening here: How can we check if an outlet is correctly grounded ? I live in a faily new appartment with good outlets, but maybe I should make sure they are OK ?

  • sj_zero
    link
    fedilink
    25 months ago

    The most important risk you face is if somehow mains voltage ends up contacting somewhere you get electrocuted and die.

    There are 2 purposes of an earth ground: First it can be used as a reference for certain signals, such as microphones. Second, it can be used to protect against turning yourself into a sparker.

    There is a clear separation between mains voltage and system voltages so it’s typically not going to be a problem, but if a little wire ends up contacting the power supply case it can become energized and things start to get really bad.

    Most of the electrical code where I live focuses on grounding as “Bonding”, which is purely safety related for giving dangerous voltages a safe place to go.

  • Possibly linux
    link
    fedilink
    English
    15 months ago

    Run the ground into the ground. You can get metal wire that would work nicely.

    • @[email protected]
      link
      fedilink
      English
      55 months ago

      Except in very rare configurations (i.e. not 99.9% of residential), you do not want to have multiple paths to ground within a system. All grounds should go to the tied ground/neutral bus in the main breaker panel, which then goes to earth via a ground rod or a clamp to a copper gas/water line, etc. Otherwise you can have current flowing in ways that the system isn’t designed for, which at the least can trip breakers and GFCIs, and at worst exceed the rating of the wires in a short condition and cause a fire.

    • @[email protected]
      link
      fedilink
      English
      15 months ago

      Except in very rare configurations (i.e. not 99.9% of residential), you do not want to have multiple paths to ground within a system. All grounds should go to the tied ground/neutral bus in the main breaker panel, which then goes to earth via a ground rod or a clamp to a copper gas/water line, etc. Otherwise you can have current flowing in ways that the system isn’t designed for, which at the least can trip breakers and GFCIs, and at worst exceed the rating of the wires in a short condition and cause a fire.

  • @[email protected]
    link
    fedilink
    English
    15 months ago

    You don’t need to have wired across the room. You can put them through the wall like every other cable. If the wire tubes are not full, it isn’t very complicated. I put my Ethernet wires in the wall.